Navigation

NLS-FM200

Newland Product
Product Information
  • Model:NLS-FM200
  • Product Category:Mobile 2D Barcode Scanner
  • Data type:1D/2D
  • Reading Mode :CMOS
  • Interface:RS232/USB/KBW
  • Wireless:None

Overview

     A mobile 2D barcode scanner mainly focusing on the 2D symbologies on the screen of mobile phone.  Can be used as a validation device in the mobile ticketing application.

Features

    ◆   High Acceptancy
          Well-designed on the light source to meets all kinds of high bright, low resolution mobile LED/LCD screen barcodes(Mainly focusing on 2D) scanning.  The acceptancy on the anti-reflection and high density barcode scanning also reaches global standard.  Covers most of the mobile phone screens from major brands for 2D symbologies scanning.
    ◆   Advance Technology 
          Thanks to the core-technology. Independent designed and manufactured by Newland Auto-ID.   Technology includes the optical, CMOS, digitizer, decoder, image processing & embedded systems.  Supports all global standard 1D barcode symbologies as well as major 2D codes (QR Code, DataMatrix, PDF417, Aztec, Maxicode, Chinese-Sensible Code & LP Code) Reading performance reaches global standard.  By using accessories provided, scan all kinds of barcodes defined by customers.

Dimension (Unit: mm)

 

Specification

Performance

Image Sensor

CMOS

Resoluing

640 * 480

Interface

RS232 / HID-KBW / UDP / USB COM Port Emulation / HID-POS

 

 

Symbologies

 

2D

PDF417, QR Code(Model 1/2), DataMatrix(ECC200, ECC000, 050, 080,
100,140),  Aztec, Chinese-Sensible Code, Maxicode, LP Code, etc.

 

1D

Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar, China post 25, Interleaved 2 of 5, ISBN/ISSN, Code 93, etc.

 

Precision

≥ 3mil

 

Light Source

LED(622 nm - 628 nm)

 

Light Intensity

290 LUX (130 mm )

 

Depth of Scan Field

0 mm ~ 450 mm

 

Print Contrast Signal

≥ 25%

 

Roll

360°

Pitch

45°

Yaw

45°

 

Illumination

0 ~ 100,000 LUX

 

Electricals

 

Power Consumption

2 W

 

Voltage

DC 5 V

 

 

Current

 

Max

400 mA

 

Working

300 mA

 

Idle

1 mA

 

Weight

250 g

 

Enviroment

 

Operate Temperature

-5℃ -  +45℃

 

Storage Temperature

-40℃ - +60℃

 

Humidity

5% - 95%(non-condensing)

 

Programming Software

Quick Set, Programming Guide, uTools Lite

Certification

FCC Part15 Class B, CE EMC Class B

Field of View
 
Decode Distances

Barcode

Density (mil)

Near (mm)

Far (mm)

Code 39

5

0

15

Code 39

10

0

25

PDF417

5

0

20

PDF417

10

0

30

QR Code

10

0

25

QR Code

15

0

36

Data Matrix

10

0

25

Data Matrix

15

0

40

0.How to confirm the types of your equipment, X+? X? or other type?
A.X+ type(EM2027 series, last number of serial number is "X+"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.
  X type(EM2100 series,last number of serial Number is "X"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.

1.How to confirm whether the driver has been installed successfully?
A.First, confirm the equipment had connected to PC and the equipment operating normally. Open: Control Panel> Device Manager> Universal Serial Bus Controller,
 If there is "Newland USB Datapipe to series Device" said connection is "USB Com Port Emuation"--COM.
 If there is "Newland USB DataPipe Device" said connection is "USB-DataPipe".
 If there is yellow "!" before the equipment, delete the equipment, and then scan detection hardware changes,  Wait for the system to automatically install the new drivers finished.

2.Whether it is necessary upgrade the driver of USB-Datapipe from the old version to the new v1.2  USB driver (vcomctrl v1.2.exe)?
A.The new driver support USB Interface of X+ : USB-DataPipe/  USB Com Port Emuation/HID-KBW. If the users of X series, had developed their own application through the USB SDK, recommendations are not updated to the latest driver.

3.If you have installed v1.2 USB driver, how to connect by USB-Datapipe?
A.If your equipment is X+ series, read the set code of USB-Datapipe.(You can download The Manual of Settings Code free from this website.) If your equipment is X series, first you should close USB to COM serve, open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, Startup Type: Manual.

4.After installed the new driver, how to find out the COM port Corresponding to the USB Com Port Emuation?
A.Open Start> all the procedures>vcomctrl>vcomctrl, you can find the number of the COM port there.

5.Why QuickSet can not connect the equipment through USB after installed v1.2 driver?
A.Confirm FAQ-1 driver has installed correctly --> Check out the number of COM port of FAQ-4 --> Confirmed equipment has been launched. Open the Quickset, select the right COM port,manual detection. If the detection failed, you can choose one of the following ways to solve the problem:
 i.Check out whether swich to HID-KBW and have set Non-HID-KBW when read The Manual of Settings Code. Change and connect it again.
 ii.If it connect through COM before, open "File>PC comm... > USB>OK" in Quickset, try whether it work.
 iii.Close Quickset, close connection then open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, and then start it again.
Connect the equipment, open Quickset, try connection through COM.
 iv.Close Quickset, close connection. Reboot the equipment, open Quickset, connect it again.

名称
大小
类别
1
2 MB
Software
2
593 KB
Drivers

暂无下载

名称
大小
类别
1
Brochures
2
Brochures

Copyright © 2008 by Newland North America Inc. All Rights Reserved